Photo gallery, Installation

General conditions

The bonds should not be subjected to tensile strain.
Press firmly to secure the adhesive tape. Ensure there is sufficient back pressure.
Windproof, airtight or rainproof seals can only be achieved on vapour retarding membranes, roof lining membranes or façade membranes that have been laid without folds or creases.

To work with the tape, temperatures must be > 5 °C during the day and night. If the initial bond is not satisfactory, a solvent (e.g. white spirits) may be applied to the grey butyl rubber side of the tape. The solvent increases the adhesiveness of the butyl rubber at low temperatures.
The tape is self-bonding under the effect of heat.

Substrate

Before adhesion is carried out, subsurfaces should be brushed off, wiped clean with a cloth or cleaned using compressed air.
Adhesion to frozen surfaces is not possible. There must be no water-repellent substances (e.g. grease or silicone) on materials to be bonded. Subsurfaces must be sufficiently dry and stable.

Permanent adhesion is achieved on woodbased panels (chipboard, OSB and veneer plywood, MDF board and wood fibre sub-roof panels).
Pretreatment with TESCON PRIMER is required in the case of adhesion to wood-fibre underlay panels and smooth mineral subsurfaces. Concrete or plaster subsurfaces must not be sandy or crumbling.

The best results in terms of structural stability are achieved on high-quality subsurfaces.
It is your responsibility to check the suitability of the subsurface; adhesion tests are recommended in certain cases.
Pretreatment with TESCON PRIMER is recommended in the case of subsurfaces with insufficient stability.



System warranty

We do not leave you on your own. Read here about how extensive the pro clima system warranty is in the worst-case scenario