Hydrosafe® high-performance vapour check with self-adhesive strips, for external insulation and roof refurbishment
Advantages
- Excellent protection against mould and moisture damage to structures thanks to humidity-variable diffusion resistance
- Easier handling: can be used with external insulation and on refurbishment projects between two layers of mineral wool insulation
- Protects building structures against weathering during the construction phase for roof pitches of 10° (2.1:12) and higher
- Protected winter building sites thanks to hydrosafe® behaviour
- Excellent values in hazardous substance testing, has been tested according to the ISO 16000 evaluation scheme
- Quick and reliable adhesion thanks to the integrated ‘connect’ self-adhesive strips on the long edges of the membrane
Areas of application
When installed directly on top of a hard subsurface underneath exterior insulation, the INTELLO X connect vapour check (alternate terms: vapour control or retarder) membrane can be combined with all fibrous insulation materials (including blown-in insulation materials).
In the case of refurbishment from the outside and installation between two layers of insulation, the choice of insulation materials for the two layers is limited to mineral or rock wool. The thickness of the external mineral wool insulation needs to be calculated on a project-specific basis; please contact Technical Support at pro clima in Germany for assistance.
This membrane can be used on building components that are diffusion-open to the outside or are diffusion-tight, e.g. pitched, flat or green roofs, after appropriate design calculations have been carried out.
When used on the inside of insulation installed between rafters or wall framework in combination with fibrous insulation mats and boards, this membrane may only be installed onto a hard subsurface or else with additional taping of membrane overlaps with TESCON VANA.
Technical specs
Material | |||
Protective and covering fleece | Polypropylene | ||
Functional film | Polyethylene copolymer | ||
Self-adhesive strips | Water-resistant SOLID adhesive | ||
Property | Regulation | Value | Regulation |
Colour | Light grey | ||
Surface weight | EN 1849-2 | 150 g/m² ; 0.5 oz/ft² | EN 1849-2 |
Thickness | EN 1849-2 | 0.45 mm ; 18 mils | EN 1849-2 |
Water vapour resistance factor µ | EN 1931 | 31 100 | EN 1931 |
sd value | EN 1931 | 14 m | EN 1931 |
sd value, humidity-variable | EN ISO 12572 | 0.25 - >25 m | EN ISO 12572 |
g value | 70 MN·s/g | ||
g value, humidity-variable | 1.25 - >125 MN·s/g | ||
Vapour permeance | ASTM E96-A | 0.23 perms | ASTM E96-A |
Vapour permeance, humidity-variable | EN ISO 12572 | < 0.13 - 13 perms | EN ISO 12572 |
Hydrosafe value (sd) | DIN 68800-2 | 2 m | DIN 68800-2 |
Surface burning characteristics | ASTM E84 | Class A (Flame Spread 0; Smoke development index 105) | ASTM E84 |
Fire class | EN 13501-1 | E | EN 13501-1 |
Outdoor exposure | 2 months | ||
Outdoor exposure for refurbishment betw. 2 insulation layers | 14 days ; 7 days at ≤10 °C (≤50 °F) | ||
Watertight joints with ‘connect’ adhesive strips or TESCON VANA tape | EN 13859-1 | W1 | EN 13859-1 |
Watertightness to liquid water | EN 1928 | W1 | EN 1928 |
Water column | EN ISO 811 | > 2 500 mm ; > 8' 2" | EN ISO 811 |
Tensile strength MD/CD | EN 12311-2 | 250 N/5 cm / 170 N/5 cm ; 29 lb/in / 19 lb/in | EN 12311-2 |
Elongation MD/CD | EN 12311-2 | 60% / 60% | EN 12311-2 |
Nail tear resistance MD/CD | EN 12310-1 | 120 N / 120 N ; 27 lbf / 27 lbf | EN 12310-1 |
Durability after artificial ageing | EN 1296 | Passed | EN 1296 |
Temperature resistance | Permanent -40 °C to 80 °C ; -40 °F to 176 °F | ||
Thermal conductivity | 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F) | ||
CE labelling | EN 13984 | Yes | EN 13984 |