Reinforced hydrosafe® vapour check made of building paper

Advantages

  • Excellent protection against damage to structures and mould thanks to humidity-variable diffusion resistance
  • Protected winter building sites thanks to hydrosafe® behaviour
  • Can be combined with all fibrous insulation materials (including blown-in insulation)
  • Ecological solution for sealing of the building envelope
  • Excellent values in hazardous substance testing, has been tested according to the ISO 16000 evaluation scheme

Areas of application

For use on roofs, walls, ceilings and floors in combination with all fibrous insulation materials, including blown-in insulation, on structures that are open or closed to diffusion on the exterior, after appropriate design calculations.

Technical specs

  Material
Sheet Building paper, glued with PE
Reinforcement Fibreglass mesh
Property Value Regulation
Colour Blue
Surface weight 190 g/m² ; 0.62 oz/ft² EN 1849-2
Thickness 0.23 mm ; 9 mils EN 1849-2
Water vapour resistance factor µ 10 000 EN 1931
sd value 2.30 m EN 1931
sd value, humidity-variable 0.40 - 4 m EN ISO 12572
g value 11.5 MN·s/g
g value, humidity-variable 2 - 20 MN·s/g
Vapour permeance 1.4 perms ASTM E96
Vapour permeance, humidity-variable 0.82 - 8.2 US perms EN ISO 12572
Hydrosafe value (sd) 2 m DIN 68800-2
Fire rating E EN 13501-1
Watertightness to liquid water NPD EN 13984
Airtightness Tested EN 12114
Tensile strength MD/CD 550 N/5 cm / 420 N/5 cm ; 63 lb/in / 48 lb/in EN 13859-1 (A)
Elongation MD/CD 5 % / 5 % EN 13859-1 (A)
Nail tear resistance MD/CD 70 N / 70 N ; 16 lbf / 16 lbf EN 13859-1 (B)
Durability after artificial ageing Passed EN 1296 / EN 1931
Temperature resistance permanent up to +40 °C ; +104 °F
Thermal conductivity 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F)
CE labelling Yes EN 13984