Flame retardant wall lining membrane for gap decking up to 30 mm (1 1/4")

connect variant with self-adhesive zones

Advantages

  • More security: flame-retardant B-s1, d0
  • Ensures reliable building components: highly permeable and, at the same time, maximum protection against driving rain
  • Not visible behind gap decking: black fleece with identification marking in the overlap area
  • Highest possible durability and thermostability thanks to the monolithic membrane
  • 2 months of outdoor exposure

Areas of Application

For use as a wall lining membrane behind closed and open facades (gap decking, up to a gap width of 30 mm / 1 1/4" - decking width = at least 3 x gap width). Installation on boarding, wood-based panels and all mat or panel-shaped thermal insulation materials.

Technical specs

  Material
Protective and covering fleece Polypropylene microfibre
Membrane monolithic
Attribute Value Norm
Colour black
Surface weight 145 g/m² ; 0.48 oz/ft² EN 1849-2
Thickness 0.5 mm ; 20 mils EN 1849-2
Water vapor resistance factor µ 160 EN ISO 12572
sd-value 0,08 m EN ISO 12572
g-value 0.4 MN·s/g
Vapour permeance 41 US perms ASTM E 96
Fire rating B - s1, d0 EN 13501-1
Outdoor exposure 2 months
Water column 10 000 mm ; 32' 10" EN ISO 811
Water tightness non-aged/aged* W1 / W1 EN 13859-2
Tensile strength MD/CD 260 N/5 cm / 225 N/5 cm ; 30 lb/in / 26 lb/in EN 13859-2 (A)
Tensile strength MD/CD aged* 260 N/5 cm / 220 N/5 cm ; 30 lb/in / 25 lb/in EN 13859-2 (A)
Elongation MD/CD 60 % / 80 % EN 13859-2 (A)
Elongation MD/CD aged* 30 % / 40 % EN 13859-2 (A)
Nail tear resistance MD/CD 190 N / 220 N ; 43 lbf / 49 lbf EN 13859-2 (B)
*) Durability after artificial ageing passed (for walls with open joints) EN 1297 / EN 1296
Flexibility at low temperature -40 °C ; -40 °F EN 1109
Temperature resistance permanent -40 °C to 80 °C ; -40 °F to 176 °F
Thermal conductivity 2.3 W/(m·K) ; 16 BTU·in/(h·ft²·F)
CE labelling yes EN 13859-2